✨ New Arrivals Just Dropped!Explore
Polypipe UFH Ultra Flexible Barrier Pipe Coil 15mm | Underfloor Heating Pipe | 50m–150m
HomeStore

Polypipe UFH Ultra Flexible Barrier Pipe Coil 15mm | Underfloor Heating Pipe | 50m–150m

Polypipe UFH Ultra Flexible Barrier Pipe Coil 15mm | Underfloor Heating Pipe | 50m–150m

15mm Barrier Pipe UFH Only — Not for Plumbing EN ISO 15876 / EN ISO 21003

The Polypipe UFH 15mm Ultra Flexible Barrier Pipe Coil is the standard pipe for all Polypipe solid floor underfloor heating installations — panel system, clip rail system, and staple systems. Made from highly flexible polybutylene with an integral oxygen barrier layer, it is significantly more flexible than standard plumbing barrier pipe, reducing installation effort and enabling tight routing in complex floor layouts. Available in five coil lengths — 50m, 80m, 100m, 120m, and 150m — allowing exact sizing to the circuit requirement. This pipe is for underfloor heating use only and must not be used for potable water, domestic hot water, or gas pipework.

Available Variants — Select Length Above

Coil Length MPN Typical Circuit Coverage Best For
50m UFH5015B Up to 11m² @ 100mm / 22m² @ 200mm Single rooms, bathrooms, single circuits in smaller zones
80m UFH8015B Up to 18m² @ 100mm / 35m² @ 200mm Medium rooms, one to two circuits, avoids excess waste on smaller projects
100m UFH10015B Up to 22m² @ 100mm / 44m² @ 200mm Most common trade size — single long circuit or two shorter circuits
120m UFH12015B Up to 26m² @ 100mm / 53m² @ 200mm Larger rooms requiring up to two full-length circuits
150m UFH15015B Up to 33m² @ 100mm / 66m² @ 200mm Large open-plan areas, multi-circuit zones, best per-metre value

Maximum single circuit length: 100m (inclusive of connection tails to and from the manifold). Do not exceed 100m per circuit — longer circuits cause excessive pressure drop and uneven flow distribution across the manifold. For areas exceeding 100m of pipe, split into multiple circuits on the manifold.

Why Ultra Flexible?

Standard polybutylene barrier pipe — as used in conventional plumbing — is designed to be self-supporting and relatively rigid. This makes it easy to run in straight lines but difficult to route through tight bends and complex patterns. Underfloor heating requires the opposite: pipe needs to be laid in continuous serpentine or spiral patterns with small-radius bends repeated dozens of times across the floor area.

Polypipe's UFH Ultra Flex pipe is specifically formulated for this application. It is significantly more flexible than standard plumbing grade barrier pipe, allowing easy routing through the castellations of the Red Floor Panel (PB08576), over the clip rail (CLIPRL), or across the floor with a staple gun, with minimal effort and without the pipe trying to spring back. When unrolling, take the pipe from the outside of the coil and unroll in the direction of travel — this prevents twisting and kinking. The Red Floor Panel guides ensure the minimum bend radius is automatically maintained, eliminating the risk of pipe deformation at bends.

Key Features & Benefits

🔄 Ultra Flexible PolybutyleneSignificantly more flexible than standard plumbing barrier pipe. Reduces installation effort — less force required to route through castellations, over clip rails, and around corners. Speeds up pipe laying considerably on larger floors.
🛡️ Oxygen Barrier LayerThe integral oxygen diffusion barrier prevents oxygen ingress into the heating water. Dissolved oxygen causes corrosion in boilers, heat exchangers, and ferrous system components. The barrier layer is a requirement for WRAS approval and is present in all Polypipe UFH barrier pipe products.
❄️ Freeze ResistantThe polybutylene material is resistant to freeze damage — the pipe will temporarily deform rather than split if water freezes inside. This provides a degree of protection in cases where a newly laid, unfilled system is exposed to frost conditions on site before the boiler is commissioned.
📏 UFH-Only — Correct StandardTested and approved to BS EN ISO 15876-1:2003 and BS EN ISO 21003-1:2008 at a maximum working pressure of 10 bar. These are the applicable standards for polybutylene barrier pipe in underfloor heating applications. Maximum operating temperature 60°C.
🔗 Polypipe System CompatibleConnects to all Polypipe stainless steel and plastic manifolds via the Polypipe push-fit adaptor sets. Compatible with both the Red Floor Panel system (PB08576) and the Clip Rail system. Use PB02911 pipe clips to secure at bends and circuit ends in the clip rail system.
📦 Multiple Lengths AvailableAvailable in five lengths from 50m to 150m, allowing the correct quantity to be specified for each circuit without waste. For multi-circuit projects, specify the length that matches the longest circuit and cut to length — the 100m coil is the most commonly specified trade length.

Coverage Calculation Guide

Use the following material requirements to estimate pipe quantities:

Pipe Centres Pipe Required Max Coverage per 100m Circuit
100mm 8.2m of pipe per m² Approx 11m² (plus tails)
200mm 4.5m of pipe per m² Approx 22m² (plus tails)
300mm (18mm pipe only) 3.3m of pipe per m² Approx 30m² (plus tails)

Always add 5–10m per circuit for connection tails (manifold to floor entry and exit, via conduit pipe CPC1525). Do not plan circuits longer than 100m inclusive of tails.

Technical Specifications

Specification Detail
Pipe diameter 15mm
Material Ultra flexible polybutylene (UFH grade)
Oxygen barrier Yes — integral diffusion barrier
Maximum operating temperature 60°C
Maximum working pressure 10 bar (tested to BS EN ISO 15876 / 21003)
Colour White
Compatible systems Red Floor Panel (PB08576), Clip Rail (CLIPRL), Staple system — all solid floor UFH applications
Not suitable for Potable cold water, domestic hot water, gas, oil, or compressed air
Connections Polypipe push-fit manifold adaptors / Polyplumb fittings
Available coil lengths 50m (UFH5015B), 80m (UFH8015B), 100m (UFH10015B), 120m (UFH12015B), 150m (UFH15015B)

⚠️ Important — UFH Pipe is Not for Plumbing

This pipe is engineered specifically for underfloor heating circuits. It must not be used for potable cold water supply, domestic hot water, gas or oil supply, or compressed air pipework. These applications require differently rated pipe materials. UFH barrier pipe used in plumbing applications may not comply with WRAS requirements for drinking water contact and could present a safety risk. Always use appropriate pipe for each application.

Frequently Asked Questions

How do I choose the right coil length?

Calculate the pipe required for your circuit area (floor area in m² × pipe density per m²) and add 5–10m for connection tails. Choose the next coil size up. For example: a 15m² floor at 200mm centres needs 15 × 4.5 = 67.5m of pipe, plus 8m of tails = 75.5m total — specify the 80m coil. Avoid over-specifying; excess pipe that has been unrolled cannot be re-used in the system as a partial circuit of reduced length would create flow imbalance.

Can I join two coils together in one circuit?

No. UFH circuits must be continuous runs of pipe with no joints within the floor structure. Joints in buried pipe create an unacceptable risk of leaks after screeding, which would require breaking out the screed to repair. Each circuit should be a single unjoined coil from manifold to manifold. The maximum circuit length of 100m prevents the need for any mid-circuit joints in practice.

Can I use this pipe with the Polypipe Overlay system?

No. The Overlay system uses 12mm barrier pipe (UFH5012B / UFH8012B). The Overlay floor panels and end returns are grooved for 12mm pipe only. The 15mm pipe is for solid screeded floor applications (panel system and clip rail system) where 15mm and 18mm pipe sizes are used. Using 15mm pipe in Overlay panels would prevent correct installation and panel joints from seating.

ℹ️ Related products: PB08576 Red Floor Panel (pipe positioning for solid floors) · CLIPRL 1m Clip Rail (alternative pipe fixing method) · PB02911 Pipe Clip Pack of 250 (clip rail system fixings) · CPC1525 / CPC2225 Conduit Pipe Coil (protects pipe tails through screed edge and manifold connections)
Select Size
From $53.85

Original: $153.86

-65%
Polypipe UFH Ultra Flexible Barrier Pipe Coil 15mm | Underfloor Heating Pipe | 50m–150m

$153.86

$53.85

Polypipe UFH Ultra Flexible Barrier Pipe Coil 15mm | Underfloor Heating Pipe | 50m–150m

15mm Barrier Pipe UFH Only — Not for Plumbing EN ISO 15876 / EN ISO 21003

The Polypipe UFH 15mm Ultra Flexible Barrier Pipe Coil is the standard pipe for all Polypipe solid floor underfloor heating installations — panel system, clip rail system, and staple systems. Made from highly flexible polybutylene with an integral oxygen barrier layer, it is significantly more flexible than standard plumbing barrier pipe, reducing installation effort and enabling tight routing in complex floor layouts. Available in five coil lengths — 50m, 80m, 100m, 120m, and 150m — allowing exact sizing to the circuit requirement. This pipe is for underfloor heating use only and must not be used for potable water, domestic hot water, or gas pipework.

Available Variants — Select Length Above

Coil Length MPN Typical Circuit Coverage Best For
50m UFH5015B Up to 11m² @ 100mm / 22m² @ 200mm Single rooms, bathrooms, single circuits in smaller zones
80m UFH8015B Up to 18m² @ 100mm / 35m² @ 200mm Medium rooms, one to two circuits, avoids excess waste on smaller projects
100m UFH10015B Up to 22m² @ 100mm / 44m² @ 200mm Most common trade size — single long circuit or two shorter circuits
120m UFH12015B Up to 26m² @ 100mm / 53m² @ 200mm Larger rooms requiring up to two full-length circuits
150m UFH15015B Up to 33m² @ 100mm / 66m² @ 200mm Large open-plan areas, multi-circuit zones, best per-metre value

Maximum single circuit length: 100m (inclusive of connection tails to and from the manifold). Do not exceed 100m per circuit — longer circuits cause excessive pressure drop and uneven flow distribution across the manifold. For areas exceeding 100m of pipe, split into multiple circuits on the manifold.

Why Ultra Flexible?

Standard polybutylene barrier pipe — as used in conventional plumbing — is designed to be self-supporting and relatively rigid. This makes it easy to run in straight lines but difficult to route through tight bends and complex patterns. Underfloor heating requires the opposite: pipe needs to be laid in continuous serpentine or spiral patterns with small-radius bends repeated dozens of times across the floor area.

Polypipe's UFH Ultra Flex pipe is specifically formulated for this application. It is significantly more flexible than standard plumbing grade barrier pipe, allowing easy routing through the castellations of the Red Floor Panel (PB08576), over the clip rail (CLIPRL), or across the floor with a staple gun, with minimal effort and without the pipe trying to spring back. When unrolling, take the pipe from the outside of the coil and unroll in the direction of travel — this prevents twisting and kinking. The Red Floor Panel guides ensure the minimum bend radius is automatically maintained, eliminating the risk of pipe deformation at bends.

Key Features & Benefits

🔄 Ultra Flexible PolybutyleneSignificantly more flexible than standard plumbing barrier pipe. Reduces installation effort — less force required to route through castellations, over clip rails, and around corners. Speeds up pipe laying considerably on larger floors.
🛡️ Oxygen Barrier LayerThe integral oxygen diffusion barrier prevents oxygen ingress into the heating water. Dissolved oxygen causes corrosion in boilers, heat exchangers, and ferrous system components. The barrier layer is a requirement for WRAS approval and is present in all Polypipe UFH barrier pipe products.
❄️ Freeze ResistantThe polybutylene material is resistant to freeze damage — the pipe will temporarily deform rather than split if water freezes inside. This provides a degree of protection in cases where a newly laid, unfilled system is exposed to frost conditions on site before the boiler is commissioned.
📏 UFH-Only — Correct StandardTested and approved to BS EN ISO 15876-1:2003 and BS EN ISO 21003-1:2008 at a maximum working pressure of 10 bar. These are the applicable standards for polybutylene barrier pipe in underfloor heating applications. Maximum operating temperature 60°C.
🔗 Polypipe System CompatibleConnects to all Polypipe stainless steel and plastic manifolds via the Polypipe push-fit adaptor sets. Compatible with both the Red Floor Panel system (PB08576) and the Clip Rail system. Use PB02911 pipe clips to secure at bends and circuit ends in the clip rail system.
📦 Multiple Lengths AvailableAvailable in five lengths from 50m to 150m, allowing the correct quantity to be specified for each circuit without waste. For multi-circuit projects, specify the length that matches the longest circuit and cut to length — the 100m coil is the most commonly specified trade length.

Coverage Calculation Guide

Use the following material requirements to estimate pipe quantities:

Pipe Centres Pipe Required Max Coverage per 100m Circuit
100mm 8.2m of pipe per m² Approx 11m² (plus tails)
200mm 4.5m of pipe per m² Approx 22m² (plus tails)
300mm (18mm pipe only) 3.3m of pipe per m² Approx 30m² (plus tails)

Always add 5–10m per circuit for connection tails (manifold to floor entry and exit, via conduit pipe CPC1525). Do not plan circuits longer than 100m inclusive of tails.

Technical Specifications

Specification Detail
Pipe diameter 15mm
Material Ultra flexible polybutylene (UFH grade)
Oxygen barrier Yes — integral diffusion barrier
Maximum operating temperature 60°C
Maximum working pressure 10 bar (tested to BS EN ISO 15876 / 21003)
Colour White
Compatible systems Red Floor Panel (PB08576), Clip Rail (CLIPRL), Staple system — all solid floor UFH applications
Not suitable for Potable cold water, domestic hot water, gas, oil, or compressed air
Connections Polypipe push-fit manifold adaptors / Polyplumb fittings
Available coil lengths 50m (UFH5015B), 80m (UFH8015B), 100m (UFH10015B), 120m (UFH12015B), 150m (UFH15015B)

⚠️ Important — UFH Pipe is Not for Plumbing

This pipe is engineered specifically for underfloor heating circuits. It must not be used for potable cold water supply, domestic hot water, gas or oil supply, or compressed air pipework. These applications require differently rated pipe materials. UFH barrier pipe used in plumbing applications may not comply with WRAS requirements for drinking water contact and could present a safety risk. Always use appropriate pipe for each application.

Frequently Asked Questions

How do I choose the right coil length?

Calculate the pipe required for your circuit area (floor area in m² × pipe density per m²) and add 5–10m for connection tails. Choose the next coil size up. For example: a 15m² floor at 200mm centres needs 15 × 4.5 = 67.5m of pipe, plus 8m of tails = 75.5m total — specify the 80m coil. Avoid over-specifying; excess pipe that has been unrolled cannot be re-used in the system as a partial circuit of reduced length would create flow imbalance.

Can I join two coils together in one circuit?

No. UFH circuits must be continuous runs of pipe with no joints within the floor structure. Joints in buried pipe create an unacceptable risk of leaks after screeding, which would require breaking out the screed to repair. Each circuit should be a single unjoined coil from manifold to manifold. The maximum circuit length of 100m prevents the need for any mid-circuit joints in practice.

Can I use this pipe with the Polypipe Overlay system?

No. The Overlay system uses 12mm barrier pipe (UFH5012B / UFH8012B). The Overlay floor panels and end returns are grooved for 12mm pipe only. The 15mm pipe is for solid screeded floor applications (panel system and clip rail system) where 15mm and 18mm pipe sizes are used. Using 15mm pipe in Overlay panels would prevent correct installation and panel joints from seating.

ℹ️ Related products: PB08576 Red Floor Panel (pipe positioning for solid floors) · CLIPRL 1m Clip Rail (alternative pipe fixing method) · PB02911 Pipe Clip Pack of 250 (clip rail system fixings) · CPC1525 / CPC2225 Conduit Pipe Coil (protects pipe tails through screed edge and manifold connections)

Product Information

Shipping & Returns

Description

15mm Barrier Pipe UFH Only — Not for Plumbing EN ISO 15876 / EN ISO 21003

The Polypipe UFH 15mm Ultra Flexible Barrier Pipe Coil is the standard pipe for all Polypipe solid floor underfloor heating installations — panel system, clip rail system, and staple systems. Made from highly flexible polybutylene with an integral oxygen barrier layer, it is significantly more flexible than standard plumbing barrier pipe, reducing installation effort and enabling tight routing in complex floor layouts. Available in five coil lengths — 50m, 80m, 100m, 120m, and 150m — allowing exact sizing to the circuit requirement. This pipe is for underfloor heating use only and must not be used for potable water, domestic hot water, or gas pipework.

Available Variants — Select Length Above

Coil Length MPN Typical Circuit Coverage Best For
50m UFH5015B Up to 11m² @ 100mm / 22m² @ 200mm Single rooms, bathrooms, single circuits in smaller zones
80m UFH8015B Up to 18m² @ 100mm / 35m² @ 200mm Medium rooms, one to two circuits, avoids excess waste on smaller projects
100m UFH10015B Up to 22m² @ 100mm / 44m² @ 200mm Most common trade size — single long circuit or two shorter circuits
120m UFH12015B Up to 26m² @ 100mm / 53m² @ 200mm Larger rooms requiring up to two full-length circuits
150m UFH15015B Up to 33m² @ 100mm / 66m² @ 200mm Large open-plan areas, multi-circuit zones, best per-metre value

Maximum single circuit length: 100m (inclusive of connection tails to and from the manifold). Do not exceed 100m per circuit — longer circuits cause excessive pressure drop and uneven flow distribution across the manifold. For areas exceeding 100m of pipe, split into multiple circuits on the manifold.

Why Ultra Flexible?

Standard polybutylene barrier pipe — as used in conventional plumbing — is designed to be self-supporting and relatively rigid. This makes it easy to run in straight lines but difficult to route through tight bends and complex patterns. Underfloor heating requires the opposite: pipe needs to be laid in continuous serpentine or spiral patterns with small-radius bends repeated dozens of times across the floor area.

Polypipe's UFH Ultra Flex pipe is specifically formulated for this application. It is significantly more flexible than standard plumbing grade barrier pipe, allowing easy routing through the castellations of the Red Floor Panel (PB08576), over the clip rail (CLIPRL), or across the floor with a staple gun, with minimal effort and without the pipe trying to spring back. When unrolling, take the pipe from the outside of the coil and unroll in the direction of travel — this prevents twisting and kinking. The Red Floor Panel guides ensure the minimum bend radius is automatically maintained, eliminating the risk of pipe deformation at bends.

Key Features & Benefits

🔄 Ultra Flexible PolybutyleneSignificantly more flexible than standard plumbing barrier pipe. Reduces installation effort — less force required to route through castellations, over clip rails, and around corners. Speeds up pipe laying considerably on larger floors.
🛡️ Oxygen Barrier LayerThe integral oxygen diffusion barrier prevents oxygen ingress into the heating water. Dissolved oxygen causes corrosion in boilers, heat exchangers, and ferrous system components. The barrier layer is a requirement for WRAS approval and is present in all Polypipe UFH barrier pipe products.
❄️ Freeze ResistantThe polybutylene material is resistant to freeze damage — the pipe will temporarily deform rather than split if water freezes inside. This provides a degree of protection in cases where a newly laid, unfilled system is exposed to frost conditions on site before the boiler is commissioned.
📏 UFH-Only — Correct StandardTested and approved to BS EN ISO 15876-1:2003 and BS EN ISO 21003-1:2008 at a maximum working pressure of 10 bar. These are the applicable standards for polybutylene barrier pipe in underfloor heating applications. Maximum operating temperature 60°C.
🔗 Polypipe System CompatibleConnects to all Polypipe stainless steel and plastic manifolds via the Polypipe push-fit adaptor sets. Compatible with both the Red Floor Panel system (PB08576) and the Clip Rail system. Use PB02911 pipe clips to secure at bends and circuit ends in the clip rail system.
📦 Multiple Lengths AvailableAvailable in five lengths from 50m to 150m, allowing the correct quantity to be specified for each circuit without waste. For multi-circuit projects, specify the length that matches the longest circuit and cut to length — the 100m coil is the most commonly specified trade length.

Coverage Calculation Guide

Use the following material requirements to estimate pipe quantities:

Pipe Centres Pipe Required Max Coverage per 100m Circuit
100mm 8.2m of pipe per m² Approx 11m² (plus tails)
200mm 4.5m of pipe per m² Approx 22m² (plus tails)
300mm (18mm pipe only) 3.3m of pipe per m² Approx 30m² (plus tails)

Always add 5–10m per circuit for connection tails (manifold to floor entry and exit, via conduit pipe CPC1525). Do not plan circuits longer than 100m inclusive of tails.

Technical Specifications

Specification Detail
Pipe diameter 15mm
Material Ultra flexible polybutylene (UFH grade)
Oxygen barrier Yes — integral diffusion barrier
Maximum operating temperature 60°C
Maximum working pressure 10 bar (tested to BS EN ISO 15876 / 21003)
Colour White
Compatible systems Red Floor Panel (PB08576), Clip Rail (CLIPRL), Staple system — all solid floor UFH applications
Not suitable for Potable cold water, domestic hot water, gas, oil, or compressed air
Connections Polypipe push-fit manifold adaptors / Polyplumb fittings
Available coil lengths 50m (UFH5015B), 80m (UFH8015B), 100m (UFH10015B), 120m (UFH12015B), 150m (UFH15015B)

⚠️ Important — UFH Pipe is Not for Plumbing

This pipe is engineered specifically for underfloor heating circuits. It must not be used for potable cold water supply, domestic hot water, gas or oil supply, or compressed air pipework. These applications require differently rated pipe materials. UFH barrier pipe used in plumbing applications may not comply with WRAS requirements for drinking water contact and could present a safety risk. Always use appropriate pipe for each application.

Frequently Asked Questions

How do I choose the right coil length?

Calculate the pipe required for your circuit area (floor area in m² × pipe density per m²) and add 5–10m for connection tails. Choose the next coil size up. For example: a 15m² floor at 200mm centres needs 15 × 4.5 = 67.5m of pipe, plus 8m of tails = 75.5m total — specify the 80m coil. Avoid over-specifying; excess pipe that has been unrolled cannot be re-used in the system as a partial circuit of reduced length would create flow imbalance.

Can I join two coils together in one circuit?

No. UFH circuits must be continuous runs of pipe with no joints within the floor structure. Joints in buried pipe create an unacceptable risk of leaks after screeding, which would require breaking out the screed to repair. Each circuit should be a single unjoined coil from manifold to manifold. The maximum circuit length of 100m prevents the need for any mid-circuit joints in practice.

Can I use this pipe with the Polypipe Overlay system?

No. The Overlay system uses 12mm barrier pipe (UFH5012B / UFH8012B). The Overlay floor panels and end returns are grooved for 12mm pipe only. The 15mm pipe is for solid screeded floor applications (panel system and clip rail system) where 15mm and 18mm pipe sizes are used. Using 15mm pipe in Overlay panels would prevent correct installation and panel joints from seating.

ℹ️ Related products: PB08576 Red Floor Panel (pipe positioning for solid floors) · CLIPRL 1m Clip Rail (alternative pipe fixing method) · PB02911 Pipe Clip Pack of 250 (clip rail system fixings) · CPC1525 / CPC2225 Conduit Pipe Coil (protects pipe tails through screed edge and manifold connections)