✨ New Arrivals Just Dropped!Explore
Mixergy 210L R290 iHP Integrated Heat Pump Cylinder | Smart Unvented DHW
HomeStore

Mixergy 210L R290 iHP Integrated Heat Pump Cylinder | Smart Unvented DHW

Mixergy 210L R290 iHP Integrated Heat Pump Cylinder | Smart Unvented DHW

Integrated Heat Pump R290 · GWP 3 210 Litres CoP 3.4 Energy Rating A+ Hot Water in 30 Min Smart App Control Duplex Stainless

The Mixergy 210L R290 iHP Integrated Heat Pump Cylinder (MX-210-IH2-579) is a smart unvented hot water cylinder with an integrated indoor R290 air-to-water heat pump — no outdoor unit, no separate plant room. Part of Mixergy's iHP X R290 range, it combines a Duplex stainless steel cylinder with a top-mounted heat pump head using patented top-down stratified heating to deliver usable hot water in under 30 minutes — up to 10× faster than conventional integrated HP cylinders — while consuming around three times less electricity than a direct electric cylinder. The cylinder connects to the Mixergy app for machine-learning schedules, time-of-use tariff optimisation, and live hot water level monitoring.

<30 min
First usable hot water (top-down partial charge)
~164 min
70% charge reheat
~234 min
100% charge reheat
59°C
Max temp — heat pump only
💡 Top-Down Advantage: Mixergy's patented stratified heating fills from the top down. Hot water becomes available at the tap within 30 minutes even from a cold cylinder — dramatically better than conventional integrated HP cylinders which must heat the full volume before any usable water is available.
  • Integrated indoor R290 heat pump — compact head unit sits on top of the cylinder, no outdoor unit or separate plant room required
  • Top-down stratified heating — usable hot water available in under 30 minutes, up to 10× faster than conventional integrated HP cylinders
  • CoP 3.4 — ErP A+ rated, delivers around 3× the energy output versus electricity input
  • 210L Duplex stainless steel cylinder — for typical family homes with moderate-to-high hot water demand
  • R290 (propane) refrigerant — GWP of 3, zero ODP, factory-charged with ~150 g
  • Heat pump achieves up to 59°C — sufficient for Legionella prevention without the backup immersion
  • 2 kW backup immersion heater (1¾" BSP, factory-fitted) for boost and emergency operation
  • Mixergy app — machine-learning scheduling, time-of-use tariff optimisation (Agile/Economy7), live level monitoring, Boost mode
  • Modular two-piece design — cylinder and heat pump head shipped separately for easier installation in tight plant spaces
  • 150mm duct connections (intake and exhaust) — airflow ~500 m³/h; requires external wall access for ductwork
  • Ambient operating range −7°C to +35°C — suitable for year-round UK use
  • G3 unvented kit included — PRV, check valve, P&T relief valve, expansion relief valve, tundish, 19L expansion vessel
  • 25-year cylinder warranty / 5-year heat pump head warranty (Mixergy standard terms)
  • Powerline-to-Ethernet adapter included — connects to broadband via Ethernet for app control
Top-Down Stratification R290 GWP=3 Duplex Stainless ML Scheduling TOU Tariff Ready No Outdoor Unit
Specification Unit MX-210-IH2-579
Model / SKU MX-210-IH2-579
Nominal Capacity L 210
Cylinder Material Duplex Stainless Steel
Dimensions (H × Ø) mm 1,885 × 580
Weight (empty) kg 94
Weight (full) kg 304
Energy Rating (ErP) A+
Coefficient of Performance (CoP) 3.4
First Usable Hot Water <30 min (top-down partial)
70% Charge Reheat (15–50°C) min ~164
100% Charge Reheat (15–50°C) min ~234
Max Temp — HP Only °C 59
Refrigerant / Charge R290 / ~150 g
Refrigerant GWP 3
Heat Pump Input Power kW 0.55
Heat Pump Max Output kW 1.5
Backup Immersion Heater kW 2 (1¾" BSP)
Ambient Air Operating Range °C −7 to +35
Sound Power Level dB(A) ~50
Air Duct Diameter mm 150
Airflow m³/h ~500
Standing Heat Loss kWh/24h 0.54–1.44
Water Connections mm 22mm compression
Expansion Vessel (included) L 19
Electrical Supply 230–240V~ / 13A / 50Hz
Cylinder Warranty 25 years
Heat Pump Head Warranty 5 years
210L Duplex stainless steel cylinder
Integrated R290 heat pump head unit
2 kW backup immersion heater (factory-fitted)
Unvented G3 kit: PRV, check valve, P&T relief, expansion relief, tundish
19L expansion vessel with mounting bracket & adaptors
Powerline-to-Ethernet adapter & Ethernet cable
Control gauge & onboard electronics
User Guide & iHP X installation/servicing manual
⚠️ Installer Requirements: Must be installed and commissioned by a G3-qualified installer in accordance with Mixergy's iHP X installation manual and current Building Regulations. Electrical connections must comply with BS 7671. F-Gas work on the refrigerant circuit requires F-Gas certification.
ℹ️ Ductwork: The iHP requires a 150mm duct (intake) and 150mm duct (exhaust) connected to the outside of the building. Both ducts should be insulated to prevent condensation. The unit is not suitable for rooms without external wall access for ductwork. Minimum room volume as per Mixergy installation guidance.
📱 App Required: The Mixergy app (iOS/Android) is required for smart scheduling and monitoring. The cylinder connects via a Powerline-to-Ethernet adapter — a broadband router connection is required near the cylinder location. It can also operate as a standard cylinder without app connectivity.
How quickly does the Mixergy 210L heat water?
The patented top-down stratification means usable hot water is available at the tap in under 30 minutes from a cold start — even before the whole cylinder is heated. A 70% charge reheat (15–50°C) takes approximately 164 minutes; a full 100% reheat takes approximately 234 minutes. This is up to 10× faster than conventional integrated HP cylinders for initial availability.
Does the Mixergy need an outdoor heat pump unit?
No. The R290 heat pump is fully integrated into the cylinder head — the entire unit is indoors. Air is drawn in via a 150mm duct from outside and discharged back outside via a second 150mm duct. No separate outdoor unit, refrigerant pipework, or commissioning by an F-Gas engineer is required for the air circuit.
What is the CoP and energy rating?
The Mixergy 210L iHP achieves a CoP of 3.4 under standard test conditions — delivering around 3.4 kWh of heat for every 1 kWh of electricity consumed. It is ErP A+ rated and uses approximately three times less electricity than a comparable direct electric cylinder.
Is it compatible with Agile / time-of-use tariffs?
Yes. The Mixergy app has built-in support for time-of-use tariffs including Octopus Agile and Economy 7. Machine learning automatically schedules heating during the cheapest tariff periods, typically overnight, to minimise running costs.
What qualifications does the installer need?
A current G3 qualification is required for unvented cylinder work. Electrical connection requires a competent electrician complying with BS 7671. No F-Gas certification is needed for the iHP air circuit as the refrigerant is factory-charged and the circuit is sealed.
What warranty applies?
Mixergy's standard terms provide a 25-year warranty on the Duplex stainless steel cylinder and a 5-year warranty on the heat pump head unit. Full warranty terms and registration requirements apply — refer to Mixergy's warranty documentation.
$1,699.64

Original: $4,856.11

-65%
Mixergy 210L R290 iHP Integrated Heat Pump Cylinder | Smart Unvented DHW

$4,856.11

$1,699.64

More Images

Mixergy 210L R290 iHP Integrated Heat Pump Cylinder | Smart Unvented DHW - Image 2
Mixergy 210L R290 iHP Integrated Heat Pump Cylinder | Smart Unvented DHW - Image 3
Mixergy 210L R290 iHP Integrated Heat Pump Cylinder | Smart Unvented DHW - Image 4
Mixergy 210L R290 iHP Integrated Heat Pump Cylinder | Smart Unvented DHW - Image 5

Mixergy 210L R290 iHP Integrated Heat Pump Cylinder | Smart Unvented DHW

Integrated Heat Pump R290 · GWP 3 210 Litres CoP 3.4 Energy Rating A+ Hot Water in 30 Min Smart App Control Duplex Stainless

The Mixergy 210L R290 iHP Integrated Heat Pump Cylinder (MX-210-IH2-579) is a smart unvented hot water cylinder with an integrated indoor R290 air-to-water heat pump — no outdoor unit, no separate plant room. Part of Mixergy's iHP X R290 range, it combines a Duplex stainless steel cylinder with a top-mounted heat pump head using patented top-down stratified heating to deliver usable hot water in under 30 minutes — up to 10× faster than conventional integrated HP cylinders — while consuming around three times less electricity than a direct electric cylinder. The cylinder connects to the Mixergy app for machine-learning schedules, time-of-use tariff optimisation, and live hot water level monitoring.

<30 min
First usable hot water (top-down partial charge)
~164 min
70% charge reheat
~234 min
100% charge reheat
59°C
Max temp — heat pump only
💡 Top-Down Advantage: Mixergy's patented stratified heating fills from the top down. Hot water becomes available at the tap within 30 minutes even from a cold cylinder — dramatically better than conventional integrated HP cylinders which must heat the full volume before any usable water is available.
  • Integrated indoor R290 heat pump — compact head unit sits on top of the cylinder, no outdoor unit or separate plant room required
  • Top-down stratified heating — usable hot water available in under 30 minutes, up to 10× faster than conventional integrated HP cylinders
  • CoP 3.4 — ErP A+ rated, delivers around 3× the energy output versus electricity input
  • 210L Duplex stainless steel cylinder — for typical family homes with moderate-to-high hot water demand
  • R290 (propane) refrigerant — GWP of 3, zero ODP, factory-charged with ~150 g
  • Heat pump achieves up to 59°C — sufficient for Legionella prevention without the backup immersion
  • 2 kW backup immersion heater (1¾" BSP, factory-fitted) for boost and emergency operation
  • Mixergy app — machine-learning scheduling, time-of-use tariff optimisation (Agile/Economy7), live level monitoring, Boost mode
  • Modular two-piece design — cylinder and heat pump head shipped separately for easier installation in tight plant spaces
  • 150mm duct connections (intake and exhaust) — airflow ~500 m³/h; requires external wall access for ductwork
  • Ambient operating range −7°C to +35°C — suitable for year-round UK use
  • G3 unvented kit included — PRV, check valve, P&T relief valve, expansion relief valve, tundish, 19L expansion vessel
  • 25-year cylinder warranty / 5-year heat pump head warranty (Mixergy standard terms)
  • Powerline-to-Ethernet adapter included — connects to broadband via Ethernet for app control
Top-Down Stratification R290 GWP=3 Duplex Stainless ML Scheduling TOU Tariff Ready No Outdoor Unit
Specification Unit MX-210-IH2-579
Model / SKU MX-210-IH2-579
Nominal Capacity L 210
Cylinder Material Duplex Stainless Steel
Dimensions (H × Ø) mm 1,885 × 580
Weight (empty) kg 94
Weight (full) kg 304
Energy Rating (ErP) A+
Coefficient of Performance (CoP) 3.4
First Usable Hot Water <30 min (top-down partial)
70% Charge Reheat (15–50°C) min ~164
100% Charge Reheat (15–50°C) min ~234
Max Temp — HP Only °C 59
Refrigerant / Charge R290 / ~150 g
Refrigerant GWP 3
Heat Pump Input Power kW 0.55
Heat Pump Max Output kW 1.5
Backup Immersion Heater kW 2 (1¾" BSP)
Ambient Air Operating Range °C −7 to +35
Sound Power Level dB(A) ~50
Air Duct Diameter mm 150
Airflow m³/h ~500
Standing Heat Loss kWh/24h 0.54–1.44
Water Connections mm 22mm compression
Expansion Vessel (included) L 19
Electrical Supply 230–240V~ / 13A / 50Hz
Cylinder Warranty 25 years
Heat Pump Head Warranty 5 years
210L Duplex stainless steel cylinder
Integrated R290 heat pump head unit
2 kW backup immersion heater (factory-fitted)
Unvented G3 kit: PRV, check valve, P&T relief, expansion relief, tundish
19L expansion vessel with mounting bracket & adaptors
Powerline-to-Ethernet adapter & Ethernet cable
Control gauge & onboard electronics
User Guide & iHP X installation/servicing manual
⚠️ Installer Requirements: Must be installed and commissioned by a G3-qualified installer in accordance with Mixergy's iHP X installation manual and current Building Regulations. Electrical connections must comply with BS 7671. F-Gas work on the refrigerant circuit requires F-Gas certification.
ℹ️ Ductwork: The iHP requires a 150mm duct (intake) and 150mm duct (exhaust) connected to the outside of the building. Both ducts should be insulated to prevent condensation. The unit is not suitable for rooms without external wall access for ductwork. Minimum room volume as per Mixergy installation guidance.
📱 App Required: The Mixergy app (iOS/Android) is required for smart scheduling and monitoring. The cylinder connects via a Powerline-to-Ethernet adapter — a broadband router connection is required near the cylinder location. It can also operate as a standard cylinder without app connectivity.
How quickly does the Mixergy 210L heat water?
The patented top-down stratification means usable hot water is available at the tap in under 30 minutes from a cold start — even before the whole cylinder is heated. A 70% charge reheat (15–50°C) takes approximately 164 minutes; a full 100% reheat takes approximately 234 minutes. This is up to 10× faster than conventional integrated HP cylinders for initial availability.
Does the Mixergy need an outdoor heat pump unit?
No. The R290 heat pump is fully integrated into the cylinder head — the entire unit is indoors. Air is drawn in via a 150mm duct from outside and discharged back outside via a second 150mm duct. No separate outdoor unit, refrigerant pipework, or commissioning by an F-Gas engineer is required for the air circuit.
What is the CoP and energy rating?
The Mixergy 210L iHP achieves a CoP of 3.4 under standard test conditions — delivering around 3.4 kWh of heat for every 1 kWh of electricity consumed. It is ErP A+ rated and uses approximately three times less electricity than a comparable direct electric cylinder.
Is it compatible with Agile / time-of-use tariffs?
Yes. The Mixergy app has built-in support for time-of-use tariffs including Octopus Agile and Economy 7. Machine learning automatically schedules heating during the cheapest tariff periods, typically overnight, to minimise running costs.
What qualifications does the installer need?
A current G3 qualification is required for unvented cylinder work. Electrical connection requires a competent electrician complying with BS 7671. No F-Gas certification is needed for the iHP air circuit as the refrigerant is factory-charged and the circuit is sealed.
What warranty applies?
Mixergy's standard terms provide a 25-year warranty on the Duplex stainless steel cylinder and a 5-year warranty on the heat pump head unit. Full warranty terms and registration requirements apply — refer to Mixergy's warranty documentation.

Product Information

Shipping & Returns

Description

Integrated Heat Pump R290 · GWP 3 210 Litres CoP 3.4 Energy Rating A+ Hot Water in 30 Min Smart App Control Duplex Stainless

The Mixergy 210L R290 iHP Integrated Heat Pump Cylinder (MX-210-IH2-579) is a smart unvented hot water cylinder with an integrated indoor R290 air-to-water heat pump — no outdoor unit, no separate plant room. Part of Mixergy's iHP X R290 range, it combines a Duplex stainless steel cylinder with a top-mounted heat pump head using patented top-down stratified heating to deliver usable hot water in under 30 minutes — up to 10× faster than conventional integrated HP cylinders — while consuming around three times less electricity than a direct electric cylinder. The cylinder connects to the Mixergy app for machine-learning schedules, time-of-use tariff optimisation, and live hot water level monitoring.

<30 min
First usable hot water (top-down partial charge)
~164 min
70% charge reheat
~234 min
100% charge reheat
59°C
Max temp — heat pump only
💡 Top-Down Advantage: Mixergy's patented stratified heating fills from the top down. Hot water becomes available at the tap within 30 minutes even from a cold cylinder — dramatically better than conventional integrated HP cylinders which must heat the full volume before any usable water is available.
  • Integrated indoor R290 heat pump — compact head unit sits on top of the cylinder, no outdoor unit or separate plant room required
  • Top-down stratified heating — usable hot water available in under 30 minutes, up to 10× faster than conventional integrated HP cylinders
  • CoP 3.4 — ErP A+ rated, delivers around 3× the energy output versus electricity input
  • 210L Duplex stainless steel cylinder — for typical family homes with moderate-to-high hot water demand
  • R290 (propane) refrigerant — GWP of 3, zero ODP, factory-charged with ~150 g
  • Heat pump achieves up to 59°C — sufficient for Legionella prevention without the backup immersion
  • 2 kW backup immersion heater (1¾" BSP, factory-fitted) for boost and emergency operation
  • Mixergy app — machine-learning scheduling, time-of-use tariff optimisation (Agile/Economy7), live level monitoring, Boost mode
  • Modular two-piece design — cylinder and heat pump head shipped separately for easier installation in tight plant spaces
  • 150mm duct connections (intake and exhaust) — airflow ~500 m³/h; requires external wall access for ductwork
  • Ambient operating range −7°C to +35°C — suitable for year-round UK use
  • G3 unvented kit included — PRV, check valve, P&T relief valve, expansion relief valve, tundish, 19L expansion vessel
  • 25-year cylinder warranty / 5-year heat pump head warranty (Mixergy standard terms)
  • Powerline-to-Ethernet adapter included — connects to broadband via Ethernet for app control
Top-Down Stratification R290 GWP=3 Duplex Stainless ML Scheduling TOU Tariff Ready No Outdoor Unit
Specification Unit MX-210-IH2-579
Model / SKU MX-210-IH2-579
Nominal Capacity L 210
Cylinder Material Duplex Stainless Steel
Dimensions (H × Ø) mm 1,885 × 580
Weight (empty) kg 94
Weight (full) kg 304
Energy Rating (ErP) A+
Coefficient of Performance (CoP) 3.4
First Usable Hot Water <30 min (top-down partial)
70% Charge Reheat (15–50°C) min ~164
100% Charge Reheat (15–50°C) min ~234
Max Temp — HP Only °C 59
Refrigerant / Charge R290 / ~150 g
Refrigerant GWP 3
Heat Pump Input Power kW 0.55
Heat Pump Max Output kW 1.5
Backup Immersion Heater kW 2 (1¾" BSP)
Ambient Air Operating Range °C −7 to +35
Sound Power Level dB(A) ~50
Air Duct Diameter mm 150
Airflow m³/h ~500
Standing Heat Loss kWh/24h 0.54–1.44
Water Connections mm 22mm compression
Expansion Vessel (included) L 19
Electrical Supply 230–240V~ / 13A / 50Hz
Cylinder Warranty 25 years
Heat Pump Head Warranty 5 years
210L Duplex stainless steel cylinder
Integrated R290 heat pump head unit
2 kW backup immersion heater (factory-fitted)
Unvented G3 kit: PRV, check valve, P&T relief, expansion relief, tundish
19L expansion vessel with mounting bracket & adaptors
Powerline-to-Ethernet adapter & Ethernet cable
Control gauge & onboard electronics
User Guide & iHP X installation/servicing manual
⚠️ Installer Requirements: Must be installed and commissioned by a G3-qualified installer in accordance with Mixergy's iHP X installation manual and current Building Regulations. Electrical connections must comply with BS 7671. F-Gas work on the refrigerant circuit requires F-Gas certification.
ℹ️ Ductwork: The iHP requires a 150mm duct (intake) and 150mm duct (exhaust) connected to the outside of the building. Both ducts should be insulated to prevent condensation. The unit is not suitable for rooms without external wall access for ductwork. Minimum room volume as per Mixergy installation guidance.
📱 App Required: The Mixergy app (iOS/Android) is required for smart scheduling and monitoring. The cylinder connects via a Powerline-to-Ethernet adapter — a broadband router connection is required near the cylinder location. It can also operate as a standard cylinder without app connectivity.
How quickly does the Mixergy 210L heat water?
The patented top-down stratification means usable hot water is available at the tap in under 30 minutes from a cold start — even before the whole cylinder is heated. A 70% charge reheat (15–50°C) takes approximately 164 minutes; a full 100% reheat takes approximately 234 minutes. This is up to 10× faster than conventional integrated HP cylinders for initial availability.
Does the Mixergy need an outdoor heat pump unit?
No. The R290 heat pump is fully integrated into the cylinder head — the entire unit is indoors. Air is drawn in via a 150mm duct from outside and discharged back outside via a second 150mm duct. No separate outdoor unit, refrigerant pipework, or commissioning by an F-Gas engineer is required for the air circuit.
What is the CoP and energy rating?
The Mixergy 210L iHP achieves a CoP of 3.4 under standard test conditions — delivering around 3.4 kWh of heat for every 1 kWh of electricity consumed. It is ErP A+ rated and uses approximately three times less electricity than a comparable direct electric cylinder.
Is it compatible with Agile / time-of-use tariffs?
Yes. The Mixergy app has built-in support for time-of-use tariffs including Octopus Agile and Economy 7. Machine learning automatically schedules heating during the cheapest tariff periods, typically overnight, to minimise running costs.
What qualifications does the installer need?
A current G3 qualification is required for unvented cylinder work. Electrical connection requires a competent electrician complying with BS 7671. No F-Gas certification is needed for the iHP air circuit as the refrigerant is factory-charged and the circuit is sealed.
What warranty applies?
Mixergy's standard terms provide a 25-year warranty on the Duplex stainless steel cylinder and a 5-year warranty on the heat pump head unit. Full warranty terms and registration requirements apply — refer to Mixergy's warranty documentation.