✨ New Arrivals Just Dropped!Explore
VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station
HomeStore

VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station

VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station

160 kW DC OutputBoost Mode 400 AAC 22 kW Included3 Vehicles SimultaneouslyIP55 / IK10CE CertifiedOCPP 1.6J4G + RFID Std.

The VEGA Chargers ALOHA Lander Plus 160 kW (D) + AC steps up the performance envelope with 160 kW of DC output power and up to 267 km of range delivered in just 15 minutes. Equipped with two CCS-2 DC connectors (250 A standard / 400 A boost) and a built-in 22 kW AC Type 2 output, it simultaneously serves up to three vehicles, automatically splitting power between sessions. Housed in a stainless steel and PUR V0 enclosure with IP55 and IK10 protection, and standard 15.6" touchscreen, RFID, 4G modem, OCPP 1.6J and HMI customisable logos, this charger is engineered for high-traffic service stations, mobility hubs and fleet operations.

Range Performance
Up to 267 km in 15 minutes of connection (based on WLTP 15 kWh/100 km average).
Typical session: 6 – 23 minutes typical session
Key Features
160 kW High-Power DC Output
Full 160 kW to a single vehicle, or intelligently split to 2 × 80 kW when both DC connectors are in use simultaneously.
Dual CCS-2 with 400 A Boost
250 A standard / 400 A in Boost mode per DC port — ensuring maximum charge speed for vehicles capable of high-rate acceptance.
Integrated 22 kW AC Output
Type 2 socket at 22 kW / 32 A operates independently of DC sessions, meaning a third vehicle can always access AC charging simultaneously.
Dynamic Load Management
Real-time power distribution across DC and AC outputs — grid-aware and automatic, with no manual configuration required.
Smart Charging & Autocharge
OCPP 1.6J cloud-based management with ISO 15118 Plug & Charge for fully automated, frictionless sessions suitable for public and fleet environments.
15.6" TFT Touchscreen & RFID
Large-format colour display with RFID reader included as standard — HMI logos fully customisable for operator or white-label branding.
Full Electrical Protection Suite
Dehn 20 kA surge protection, MCB curve C protection per output, RCD 30 mA Type A, and DC isolation monitoring and fuse on every DC connector.
Heavy-Duty Ground Installation
Forklift or eyebolt placement onto anchor bolt or structural foundation — rated to IK10 for vandal and impact resistance in demanding public locations.
Typical Applications
Service Stations & Mobility Hubs
Office Buildings & Workplaces
Malls & Supermarkets
Public & Private Car Parks
Corporate Fleets & Car Sharing
Service Vehicles & Public Transport
Technical Specifications
AC INPUT
Supply Voltage 400 Vac ± 10% (3P+N+PE)
Frequency 50 / 60 Hz
Nominal Input Current 281 A (with AC output)
Apparent Power 195 kVA (with AC output)
Power Factor > 0.99
Efficiency > 95% at nominal power
THDi < 5%
Standby Consumption < 60 W
Earthing System TT / TN-S
DC OUTPUT
Max. Output Power 160 kW single / 2 × 80 kW simultaneous
Max. Output Current 250 A (400 A Boost*) / 2 × 200 A simultaneous
Output Voltage Range 150 – 1000 Vdc
DC Connectors CCS-2 + CCS-2 (4 m cables; optional 5 or 7 m)
Metering DC Official meter certified (optional)
AC OUTPUT
Max. AC Output Power 22 kW
AC Output Voltage 400 / 230 Vac ± 10% (3P+N+PE)
Max. AC Output Current 32 A
AC Connector Type 2 (Socket)
Metering AC Official meter certified (standard)
MECHANICAL
Dimensions (H × W × D) 2000 mm × 900 mm × 450 mm
Weight 435 kg
Mechanical Impact Protection IK10
Housing Material Stainless steel and PUR (V0) — customisable colour
Installation Method Ground mount — anchor bolt or structural foundation; forklift / eyebolt unloading
ENVIRONMENT
Ingress Protection IP55
Operating Temperature -10°C to +55°C (-30°C to +55°C with optional heater)
Storage Temperature -35°C to +70°C
Relative Humidity 5% to 95% non-condensing
Cooling System Exhaust fan
Noise Level ≤ 60 dBA (1 m, all directions)
Max. Altitude 2000 m
GENERAL
User Interface 15.6" TFT colour touchscreen (standard)
Communication Protocol OCPP 1.6J; Modbus TCP; Modbus RTU
Communication Interface 4G (standard); RS485; Ethernet
Access & ID RFID reader (standard) — MIFARE Classic / DESfire EV1, EV2; NFC Type 4; Autocharge; PIN code; White list
HMI Branding Customisable logos (standard)
Payment Terminal Cashless payment terminal (optional)
Status Lights RGB LED per charging connector
STANDARDS & CERTIFICATIONS
IEC / DIN / ISO IEC 61851-1/21-2/23/24; IEC 62196-1/2/3; IEC 61000; DIN70121; ISO 15118-2/-3; CHAdeMO 1.2
EU Directives LVD 2014/35/EU; EMC 2014/30/EU; RED 2014/53/EU
Mark CE
ℹ Installation Note: This product requires installation by a qualified electrician. Ensure supply capacity, earthing system and protection devices comply with local wiring regulations and the technical specification above. Contact your distributor for a pre-installation site assessment.
Frequently Asked Questions
What does Boost mode deliver on the 160 kW model?
In Boost mode, under specific temperature conditions and with limited session duration, each DC output can deliver up to 400 A — significantly above the 250 A standard rating — for vehicles capable of accepting higher charge rates.
How is power distributed during simultaneous charging?
When both DC connectors are active simultaneously, Dynamic Load Management splits the total 160 kW to 2 × 80 kW. The AC Type 2 output operates fully independently at up to 22 kW alongside both DC sessions, enabling true three-vehicle simultaneous charging.
What makes this suitable for high-traffic service stations?
The combination of 160 kW DC power, Boost mode capability, simultaneous three-vehicle charging, IP55 outdoor protection and IK10 impact resistance makes it suited to motorway service areas and busy mobility hubs where uptime and throughput are critical.
Is a separate electricity meter required for billing?
An official certified AC meter is included as standard. An optional DC official meter can be added for DC output billing or regulatory compliance. Both outputs support individual metering for accurate energy accounting.
What input supply does this unit require?
A three-phase 400 Vac supply (3P+N+PE) with a nominal input current of 281 A (with AC output active). Grid capacity should be confirmed with a qualified electrician or DNO before installation.
Related Products
ALOHA Lander Plus 120 kW (D)+AC
SKU: VG94L12
ALOHA Lander Plus 240 kW (D)+AC
SKU: VG94L24
$27,676.54

Original: $79,075.82

-65%
VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station

$79,075.82

$27,676.54

More Images

VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station - Image 2
VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station - Image 3
VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station - Image 4
VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station - Image 5
VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station - Image 6
VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station - Image 7

VEGA Chargers ALOHA Lander Plus 160kW DC Fast Charger – Dual CCS2 + AC Type 2 EV Charging Station

160 kW DC OutputBoost Mode 400 AAC 22 kW Included3 Vehicles SimultaneouslyIP55 / IK10CE CertifiedOCPP 1.6J4G + RFID Std.

The VEGA Chargers ALOHA Lander Plus 160 kW (D) + AC steps up the performance envelope with 160 kW of DC output power and up to 267 km of range delivered in just 15 minutes. Equipped with two CCS-2 DC connectors (250 A standard / 400 A boost) and a built-in 22 kW AC Type 2 output, it simultaneously serves up to three vehicles, automatically splitting power between sessions. Housed in a stainless steel and PUR V0 enclosure with IP55 and IK10 protection, and standard 15.6" touchscreen, RFID, 4G modem, OCPP 1.6J and HMI customisable logos, this charger is engineered for high-traffic service stations, mobility hubs and fleet operations.

Range Performance
Up to 267 km in 15 minutes of connection (based on WLTP 15 kWh/100 km average).
Typical session: 6 – 23 minutes typical session
Key Features
160 kW High-Power DC Output
Full 160 kW to a single vehicle, or intelligently split to 2 × 80 kW when both DC connectors are in use simultaneously.
Dual CCS-2 with 400 A Boost
250 A standard / 400 A in Boost mode per DC port — ensuring maximum charge speed for vehicles capable of high-rate acceptance.
Integrated 22 kW AC Output
Type 2 socket at 22 kW / 32 A operates independently of DC sessions, meaning a third vehicle can always access AC charging simultaneously.
Dynamic Load Management
Real-time power distribution across DC and AC outputs — grid-aware and automatic, with no manual configuration required.
Smart Charging & Autocharge
OCPP 1.6J cloud-based management with ISO 15118 Plug & Charge for fully automated, frictionless sessions suitable for public and fleet environments.
15.6" TFT Touchscreen & RFID
Large-format colour display with RFID reader included as standard — HMI logos fully customisable for operator or white-label branding.
Full Electrical Protection Suite
Dehn 20 kA surge protection, MCB curve C protection per output, RCD 30 mA Type A, and DC isolation monitoring and fuse on every DC connector.
Heavy-Duty Ground Installation
Forklift or eyebolt placement onto anchor bolt or structural foundation — rated to IK10 for vandal and impact resistance in demanding public locations.
Typical Applications
Service Stations & Mobility Hubs
Office Buildings & Workplaces
Malls & Supermarkets
Public & Private Car Parks
Corporate Fleets & Car Sharing
Service Vehicles & Public Transport
Technical Specifications
AC INPUT
Supply Voltage 400 Vac ± 10% (3P+N+PE)
Frequency 50 / 60 Hz
Nominal Input Current 281 A (with AC output)
Apparent Power 195 kVA (with AC output)
Power Factor > 0.99
Efficiency > 95% at nominal power
THDi < 5%
Standby Consumption < 60 W
Earthing System TT / TN-S
DC OUTPUT
Max. Output Power 160 kW single / 2 × 80 kW simultaneous
Max. Output Current 250 A (400 A Boost*) / 2 × 200 A simultaneous
Output Voltage Range 150 – 1000 Vdc
DC Connectors CCS-2 + CCS-2 (4 m cables; optional 5 or 7 m)
Metering DC Official meter certified (optional)
AC OUTPUT
Max. AC Output Power 22 kW
AC Output Voltage 400 / 230 Vac ± 10% (3P+N+PE)
Max. AC Output Current 32 A
AC Connector Type 2 (Socket)
Metering AC Official meter certified (standard)
MECHANICAL
Dimensions (H × W × D) 2000 mm × 900 mm × 450 mm
Weight 435 kg
Mechanical Impact Protection IK10
Housing Material Stainless steel and PUR (V0) — customisable colour
Installation Method Ground mount — anchor bolt or structural foundation; forklift / eyebolt unloading
ENVIRONMENT
Ingress Protection IP55
Operating Temperature -10°C to +55°C (-30°C to +55°C with optional heater)
Storage Temperature -35°C to +70°C
Relative Humidity 5% to 95% non-condensing
Cooling System Exhaust fan
Noise Level ≤ 60 dBA (1 m, all directions)
Max. Altitude 2000 m
GENERAL
User Interface 15.6" TFT colour touchscreen (standard)
Communication Protocol OCPP 1.6J; Modbus TCP; Modbus RTU
Communication Interface 4G (standard); RS485; Ethernet
Access & ID RFID reader (standard) — MIFARE Classic / DESfire EV1, EV2; NFC Type 4; Autocharge; PIN code; White list
HMI Branding Customisable logos (standard)
Payment Terminal Cashless payment terminal (optional)
Status Lights RGB LED per charging connector
STANDARDS & CERTIFICATIONS
IEC / DIN / ISO IEC 61851-1/21-2/23/24; IEC 62196-1/2/3; IEC 61000; DIN70121; ISO 15118-2/-3; CHAdeMO 1.2
EU Directives LVD 2014/35/EU; EMC 2014/30/EU; RED 2014/53/EU
Mark CE
ℹ Installation Note: This product requires installation by a qualified electrician. Ensure supply capacity, earthing system and protection devices comply with local wiring regulations and the technical specification above. Contact your distributor for a pre-installation site assessment.
Frequently Asked Questions
What does Boost mode deliver on the 160 kW model?
In Boost mode, under specific temperature conditions and with limited session duration, each DC output can deliver up to 400 A — significantly above the 250 A standard rating — for vehicles capable of accepting higher charge rates.
How is power distributed during simultaneous charging?
When both DC connectors are active simultaneously, Dynamic Load Management splits the total 160 kW to 2 × 80 kW. The AC Type 2 output operates fully independently at up to 22 kW alongside both DC sessions, enabling true three-vehicle simultaneous charging.
What makes this suitable for high-traffic service stations?
The combination of 160 kW DC power, Boost mode capability, simultaneous three-vehicle charging, IP55 outdoor protection and IK10 impact resistance makes it suited to motorway service areas and busy mobility hubs where uptime and throughput are critical.
Is a separate electricity meter required for billing?
An official certified AC meter is included as standard. An optional DC official meter can be added for DC output billing or regulatory compliance. Both outputs support individual metering for accurate energy accounting.
What input supply does this unit require?
A three-phase 400 Vac supply (3P+N+PE) with a nominal input current of 281 A (with AC output active). Grid capacity should be confirmed with a qualified electrician or DNO before installation.
Related Products
ALOHA Lander Plus 120 kW (D)+AC
SKU: VG94L12
ALOHA Lander Plus 240 kW (D)+AC
SKU: VG94L24

Product Information

Shipping & Returns

Description

160 kW DC OutputBoost Mode 400 AAC 22 kW Included3 Vehicles SimultaneouslyIP55 / IK10CE CertifiedOCPP 1.6J4G + RFID Std.

The VEGA Chargers ALOHA Lander Plus 160 kW (D) + AC steps up the performance envelope with 160 kW of DC output power and up to 267 km of range delivered in just 15 minutes. Equipped with two CCS-2 DC connectors (250 A standard / 400 A boost) and a built-in 22 kW AC Type 2 output, it simultaneously serves up to three vehicles, automatically splitting power between sessions. Housed in a stainless steel and PUR V0 enclosure with IP55 and IK10 protection, and standard 15.6" touchscreen, RFID, 4G modem, OCPP 1.6J and HMI customisable logos, this charger is engineered for high-traffic service stations, mobility hubs and fleet operations.

Range Performance
Up to 267 km in 15 minutes of connection (based on WLTP 15 kWh/100 km average).
Typical session: 6 – 23 minutes typical session
Key Features
160 kW High-Power DC Output
Full 160 kW to a single vehicle, or intelligently split to 2 × 80 kW when both DC connectors are in use simultaneously.
Dual CCS-2 with 400 A Boost
250 A standard / 400 A in Boost mode per DC port — ensuring maximum charge speed for vehicles capable of high-rate acceptance.
Integrated 22 kW AC Output
Type 2 socket at 22 kW / 32 A operates independently of DC sessions, meaning a third vehicle can always access AC charging simultaneously.
Dynamic Load Management
Real-time power distribution across DC and AC outputs — grid-aware and automatic, with no manual configuration required.
Smart Charging & Autocharge
OCPP 1.6J cloud-based management with ISO 15118 Plug & Charge for fully automated, frictionless sessions suitable for public and fleet environments.
15.6" TFT Touchscreen & RFID
Large-format colour display with RFID reader included as standard — HMI logos fully customisable for operator or white-label branding.
Full Electrical Protection Suite
Dehn 20 kA surge protection, MCB curve C protection per output, RCD 30 mA Type A, and DC isolation monitoring and fuse on every DC connector.
Heavy-Duty Ground Installation
Forklift or eyebolt placement onto anchor bolt or structural foundation — rated to IK10 for vandal and impact resistance in demanding public locations.
Typical Applications
Service Stations & Mobility Hubs
Office Buildings & Workplaces
Malls & Supermarkets
Public & Private Car Parks
Corporate Fleets & Car Sharing
Service Vehicles & Public Transport
Technical Specifications
AC INPUT
Supply Voltage 400 Vac ± 10% (3P+N+PE)
Frequency 50 / 60 Hz
Nominal Input Current 281 A (with AC output)
Apparent Power 195 kVA (with AC output)
Power Factor > 0.99
Efficiency > 95% at nominal power
THDi < 5%
Standby Consumption < 60 W
Earthing System TT / TN-S
DC OUTPUT
Max. Output Power 160 kW single / 2 × 80 kW simultaneous
Max. Output Current 250 A (400 A Boost*) / 2 × 200 A simultaneous
Output Voltage Range 150 – 1000 Vdc
DC Connectors CCS-2 + CCS-2 (4 m cables; optional 5 or 7 m)
Metering DC Official meter certified (optional)
AC OUTPUT
Max. AC Output Power 22 kW
AC Output Voltage 400 / 230 Vac ± 10% (3P+N+PE)
Max. AC Output Current 32 A
AC Connector Type 2 (Socket)
Metering AC Official meter certified (standard)
MECHANICAL
Dimensions (H × W × D) 2000 mm × 900 mm × 450 mm
Weight 435 kg
Mechanical Impact Protection IK10
Housing Material Stainless steel and PUR (V0) — customisable colour
Installation Method Ground mount — anchor bolt or structural foundation; forklift / eyebolt unloading
ENVIRONMENT
Ingress Protection IP55
Operating Temperature -10°C to +55°C (-30°C to +55°C with optional heater)
Storage Temperature -35°C to +70°C
Relative Humidity 5% to 95% non-condensing
Cooling System Exhaust fan
Noise Level ≤ 60 dBA (1 m, all directions)
Max. Altitude 2000 m
GENERAL
User Interface 15.6" TFT colour touchscreen (standard)
Communication Protocol OCPP 1.6J; Modbus TCP; Modbus RTU
Communication Interface 4G (standard); RS485; Ethernet
Access & ID RFID reader (standard) — MIFARE Classic / DESfire EV1, EV2; NFC Type 4; Autocharge; PIN code; White list
HMI Branding Customisable logos (standard)
Payment Terminal Cashless payment terminal (optional)
Status Lights RGB LED per charging connector
STANDARDS & CERTIFICATIONS
IEC / DIN / ISO IEC 61851-1/21-2/23/24; IEC 62196-1/2/3; IEC 61000; DIN70121; ISO 15118-2/-3; CHAdeMO 1.2
EU Directives LVD 2014/35/EU; EMC 2014/30/EU; RED 2014/53/EU
Mark CE
ℹ Installation Note: This product requires installation by a qualified electrician. Ensure supply capacity, earthing system and protection devices comply with local wiring regulations and the technical specification above. Contact your distributor for a pre-installation site assessment.
Frequently Asked Questions
What does Boost mode deliver on the 160 kW model?
In Boost mode, under specific temperature conditions and with limited session duration, each DC output can deliver up to 400 A — significantly above the 250 A standard rating — for vehicles capable of accepting higher charge rates.
How is power distributed during simultaneous charging?
When both DC connectors are active simultaneously, Dynamic Load Management splits the total 160 kW to 2 × 80 kW. The AC Type 2 output operates fully independently at up to 22 kW alongside both DC sessions, enabling true three-vehicle simultaneous charging.
What makes this suitable for high-traffic service stations?
The combination of 160 kW DC power, Boost mode capability, simultaneous three-vehicle charging, IP55 outdoor protection and IK10 impact resistance makes it suited to motorway service areas and busy mobility hubs where uptime and throughput are critical.
Is a separate electricity meter required for billing?
An official certified AC meter is included as standard. An optional DC official meter can be added for DC output billing or regulatory compliance. Both outputs support individual metering for accurate energy accounting.
What input supply does this unit require?
A three-phase 400 Vac supply (3P+N+PE) with a nominal input current of 281 A (with AC output active). Grid capacity should be confirmed with a qualified electrician or DNO before installation.
Related Products
ALOHA Lander Plus 120 kW (D)+AC
SKU: VG94L12
ALOHA Lander Plus 240 kW (D)+AC
SKU: VG94L24