Mut Meccanica Tovo SF 3‑Port Spring Return Diverting Valve is a 28 mm compression motorised zone valve designed for high‑flow heat pump systems. It offers very low pressure drop, fast spring‑return operation and an integrated microswitch for simple control of auxiliary loads.

Key Features

  • 28 mm 3‑port diverting valve – compression connections for straightforward integration into larger‑bore primary pipework on heat pump and cylinder circuits.
  • Spring‑return operation – fails to a safe default position on power loss, helping protect the system and simplify control strategies.
  • High Kvs value (12.6) – very low pressure drop, ideal for modern high‑flow, low‑temperature heat pump systems.
  • Integral microswitch – built‑in auxiliary switch for starting a secondary pump or signalling to a controller when the valve has reached position.
  • 12‑month warranty – supplied with a 12‑month manufacturer’s warranty from date of manufacture.

Applications

  • Diverting heat pump output between a hot water cylinder coil and a space heating circuit.
  • Use as a primary diverting valve in low‑temperature heating systems where low resistance is critical.
  • Replacing standard mid‑position or diverter valves where higher flow rates and reliability are required.

Technical Overview

  • Connections: 28 mm compression, brass valve body.
  • Function: 3‑port diverting valve with motor drive and spring return.
  • Flow capacity: Kvs 12.6 for excellent flow with minimal head loss.
  • Electrical: 230 V a.c. motorised actuator with auxiliary microswitch for external control/load switching.

Installation Notes

  • Install in accordance with the system design so that the default (spring‑return) position is the preferred fail‑safe flow path.
  • Pipework should be well‑supported, flushed and cleaned before commissioning to protect the valve internals.
  • All wiring must follow the manufacturer’s wiring diagram, with the microswitch correctly integrated to control pumps or system interlocks.
$155.21
Mut Meccanica Tovo SF 3‑Port Spring Return Diverting Valve
$155.21

More Images

Mut Meccanica Tovo SF 3‑Port Spring Return Diverting Valve - Image 2

Mut Meccanica Tovo SF 3‑Port Spring Return Diverting Valve

Mut Meccanica Tovo SF 3‑Port Spring Return Diverting Valve is a 28 mm compression motorised zone valve designed for high‑flow heat pump systems. It offers very low pressure drop, fast spring‑return operation and an integrated microswitch for simple control of auxiliary loads.

Key Features

  • 28 mm 3‑port diverting valve – compression connections for straightforward integration into larger‑bore primary pipework on heat pump and cylinder circuits.
  • Spring‑return operation – fails to a safe default position on power loss, helping protect the system and simplify control strategies.
  • High Kvs value (12.6) – very low pressure drop, ideal for modern high‑flow, low‑temperature heat pump systems.
  • Integral microswitch – built‑in auxiliary switch for starting a secondary pump or signalling to a controller when the valve has reached position.
  • 12‑month warranty – supplied with a 12‑month manufacturer’s warranty from date of manufacture.

Applications

  • Diverting heat pump output between a hot water cylinder coil and a space heating circuit.
  • Use as a primary diverting valve in low‑temperature heating systems where low resistance is critical.
  • Replacing standard mid‑position or diverter valves where higher flow rates and reliability are required.

Technical Overview

  • Connections: 28 mm compression, brass valve body.
  • Function: 3‑port diverting valve with motor drive and spring return.
  • Flow capacity: Kvs 12.6 for excellent flow with minimal head loss.
  • Electrical: 230 V a.c. motorised actuator with auxiliary microswitch for external control/load switching.

Installation Notes

  • Install in accordance with the system design so that the default (spring‑return) position is the preferred fail‑safe flow path.
  • Pipework should be well‑supported, flushed and cleaned before commissioning to protect the valve internals.
  • All wiring must follow the manufacturer’s wiring diagram, with the microswitch correctly integrated to control pumps or system interlocks.

Product Information

Shipping & Returns

Description

Mut Meccanica Tovo SF 3‑Port Spring Return Diverting Valve is a 28 mm compression motorised zone valve designed for high‑flow heat pump systems. It offers very low pressure drop, fast spring‑return operation and an integrated microswitch for simple control of auxiliary loads.

Key Features

  • 28 mm 3‑port diverting valve – compression connections for straightforward integration into larger‑bore primary pipework on heat pump and cylinder circuits.
  • Spring‑return operation – fails to a safe default position on power loss, helping protect the system and simplify control strategies.
  • High Kvs value (12.6) – very low pressure drop, ideal for modern high‑flow, low‑temperature heat pump systems.
  • Integral microswitch – built‑in auxiliary switch for starting a secondary pump or signalling to a controller when the valve has reached position.
  • 12‑month warranty – supplied with a 12‑month manufacturer’s warranty from date of manufacture.

Applications

  • Diverting heat pump output between a hot water cylinder coil and a space heating circuit.
  • Use as a primary diverting valve in low‑temperature heating systems where low resistance is critical.
  • Replacing standard mid‑position or diverter valves where higher flow rates and reliability are required.

Technical Overview

  • Connections: 28 mm compression, brass valve body.
  • Function: 3‑port diverting valve with motor drive and spring return.
  • Flow capacity: Kvs 12.6 for excellent flow with minimal head loss.
  • Electrical: 230 V a.c. motorised actuator with auxiliary microswitch for external control/load switching.

Installation Notes

  • Install in accordance with the system design so that the default (spring‑return) position is the preferred fail‑safe flow path.
  • Pipework should be well‑supported, flushed and cleaned before commissioning to protect the valve internals.
  • All wiring must follow the manufacturer’s wiring diagram, with the microswitch correctly integrated to control pumps or system interlocks.